View CSAF
Summary
Successful exploitation of these vulnerabilities could allow an attacker to view video information without authentication.
The following versions of Swann Communications SWIFI-SE2KIC are affected:
- SWIFI-SE2KIC firmware <=2.0.22 (CVE-2026-107605, CVE-2026-107606, CVE-2026-107607)
| CVSS |
Vendor |
Equipment |
| v3 6.2 |
Swann Communications |
SWIFI-SE2KIC firmware |
| 1 Vulnerability |
| Missing Authentication for Critical Function |
Background
- Critical Infrastructure Sectors: Commercial Facilities
- Countries/Areas Deployed: Worldwide
- Company Headquarters Location: Australia
Vulnerabilities
CVE-2026-107605
SWIFI-SE2KIC firmware versions 2.0.22 and prior are vulnerable to a Missing Authentication for Critical Function vulnerability that could allow an attacker on the local network to view live video feed without authentication.
1 Affected Product
Swann Communications SWIFI-SE2KIC firmware: <=2.0.22
Product Status: known_affected
Remediations
Mitigation
Swann Communications has provided the following interim security measures. For more information, contact Swann Communications https://support.swann.com/hc/en-us/requests/new.
Mitigation
Keep the camera behind a secured router and firewall.
Mitigation
Avoid exposing RTSP services to the internet through port forwarding, DMZ configurations, or direct public IP access.
Mitigation
Ensure the router and associated accounts use strong, unique passwords.
Mitigation
Keep device firmware updated when new releases become available.
Additional Metrics
Relevant CWE: CWE-306 Missing Authentication for Critical Function
View CVE Details
CVE-2026-107606
SWIFI-SE2KIC firmware versions 2.0.22 and prior are vulnerable to a Missing Authentication for Critical Function vulnerability that could allow an attacker on the local network to retrieve a snapshot of the live feed without authentication.
2 Affected Products
Swann Communications SWIFI-SE2KIC firmware: <=2.0.22
Product Status: known_affected
Remediations
Mitigation
Swann Communications has provided the following interim security measures. For more information, contact Swann Communications https://support.swann.com/hc/en-us/requests/new.
Mitigation
Keep the camera behind a secured router and firewall.
Mitigation
Avoid exposing RTSP services to the internet through port forwarding, DMZ configurations, or direct public IP access.
Mitigation
Ensure the router and associated accounts use strong, unique passwords.
Mitigation
Keep device firmware updated when new releases become available.
Swann Communications SWIFI-SE2KIC firmware: <=2.0.22
Product Status: known_affected
Remediations
Mitigation
Swann Communications has provided the following interim security measures. For more information, contact Swann Communications https://support.swann.com/hc/en-us/requests/new.
Mitigation
Keep the camera behind a secured router and firewall.
Mitigation
Avoid exposing RTSP services to the internet through port forwarding, DMZ configurations, or direct public IP access.
Mitigation
Ensure the router and associated accounts use strong, unique passwords.
Mitigation
Keep device firmware updated when new releases become available.
Additional Metrics
Relevant CWE: CWE-306 Missing Authentication for Critical Function
View CVE Details
CVE-2026-107607
SWIFI-SE2KIC firmware versions 2.0.22 and prior are vulnerable to a Missing Authentication for Critical Function vulnerability that could allow an attacker on the local network to access a real-time video stream without authentication.
3 Affected Products
Swann Communications SWIFI-SE2KIC firmware: <=2.0.22
Product Status: known_affected
Remediations
Mitigation
Swann Communications has provided the following interim security measures. For more information, contact Swann Communications https://support.swann.com/hc/en-us/requests/new.
Mitigation
Keep the camera behind a secured router and firewall.
Mitigation
Avoid exposing RTSP services to the internet through port forwarding, DMZ configurations, or direct public IP access.
Mitigation
Ensure the router and associated accounts use strong, unique passwords.
Mitigation
Keep device firmware updated when new releases become available.
Swann Communications SWIFI-SE2KIC firmware: <=2.0.22
Product Status: known_affected
Remediations
Mitigation
Swann Communications has provided the following interim security measures. For more information, contact Swann Communications https://support.swann.com/hc/en-us/requests/new.
Mitigation
Keep the camera behind a secured router and firewall.
Mitigation
Avoid exposing RTSP services to the internet through port forwarding, DMZ configurations, or direct public IP access.
Mitigation
Ensure the router and associated accounts use strong, unique passwords.
Mitigation
Keep device firmware updated when new releases become available.
Swann Communications SWIFI-SE2KIC firmware: <=2.0.22
Product Status: known_affected
Remediations
Mitigation
Swann Communications has provided the following interim security measures. For more information, contact Swann Communications https://support.swann.com/hc/en-us/requests/new.
Mitigation
Keep the camera behind a secured router and firewall.
Mitigation
Avoid exposing RTSP services to the internet through port forwarding, DMZ configurations, or direct public IP access.
Mitigation
Ensure the router and associated accounts use strong, unique passwords.
Mitigation
Keep device firmware updated when new releases become available.
Additional Metrics
Relevant CWE: CWE-306 Missing Authentication for Critical Function
View CVE Details
Acknowledgments
- Elliott Phillips reported these vulnerabilities to CISA.
Legal Notice and Terms of Use
This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy).
Recommended Practices
CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities.
- Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
- Locate control system networks and remote devices behind firewalls and isolating them from business networks.
- When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
CISA also recommends users take the following measures to protect themselves from social engineering attacks:
- Do not click web links or open attachments in unsolicited email messages.
- Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.
- Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.
No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. These vulnerabilities are not exploitable remotely.
Revision History
- Initial Release Date: 2026-10-13
| Date |
Revision |
Summary |
| 2026-10-13 |
1 |
Initial Publication |
Legal Notice and Terms of Use